Samsung ML 1610, 2010, 2015, 2510, 2571N fuse

Selasa, 17 Januari 2012

0 komentar


Fuse is needed to reset the counter when a new cartridge is used
This fuse is 250mAh and 3/4" inch long (20 mm) round glass with metal ends. It could be used with Samsung ML-1610 ML-2010 ML2010 ML-2015 ML2015 ML-2510 ML2510 ML-2571N ML2571N series For P/# ML-2010D3 and ML-1610D2 toner cartridge.


Where to buy it: click here

Read More..

Message "096: Fatal Error 02" with Oki printers

0 komentar
096-02 error is a problem with the finisher.
That's a "tray raise or lowering error".

Solution 1:
Check and clean the upper limit switch. 
Solution 2:
Replace the upper limet switch
Solution 3:
Check the shift motor operation and finisher control PCB board. If the motor has failed, you need to replace it, and perhaps the control PCB too. More information click here

Read More..

Canon Pixma MP530 printer

0 komentar
Download:
Cartridges:
Parts:

Troubleshooting:
Error 5B00; the waste ink counter need to be resetted:Turn off the printer
Hold the Resume Button (red circle in the triangle), add a printer (click “Power”) an indicator light green.
Hold the Power Button, release the Resume Button.
Not releasing the Power Button, double click “Resume” and release Both Buttons.
Click “Resume” for Four times
Once you click “Power”, to confirm the selected action (reset counter absorber). To disable the printer “Power” button to click again. More information click here
Read More..

Brother MFC-425CN printer

0 komentar
Download:

Cartridges:

Troubleshooting:
How to reset waste ink counter:Machine off
Switch on the machine while holding down the “menu”button until all the leds are flashing on/off. Now you are in “maintenance” mode.
press 80
press the “mono start” button several times until you see “purge: xxxx”
press “2783” in order to reset the purge counter. You will see: “purge:0000”
press “99” to exit the maintenance mode. More information click here

Read More..

Canon Pixma MP495 printer

0 komentar
Downloads:

Cartridges:

Troubleshooting:
Disconnect the power cable
Hold on "Black", "Color", "Stop/Reset" and "Power" buttons.
Without release them, plug the power cable in. Ink cartridge reset (ship reset):Solution 1 : When "empty cartridge" is displayed, Hold on the "cancel" button until "processing"appears.
Solution 2: Hold on the "Stop" button until "processing" appears Hold on the "Stop" button for 5 seconds. More information click here
Read More..

Reset transfert belt counter on Xerox Phaser 6110 MFP

0 komentar

Sometimes, when you have replaced the Image Transfer Belt, the printer still does not work. You will have to reset the counter.


Procedure:
Enter Service Mode by pressing [MENU] [#] [1] [9] [3] [4] quickly.Select Tech MenuSelect DataSetupArrow to Clear Counts and press EnterEnter Password 1934Arrow to Transfer Belt and press Enter.
The display will show Clearing Counts and then return you to the Tech Menu. Press exit several times to exit the Tech Menu and then power cycle the printer. More information click here

Read More..

How to solve error 6A90 or "APP sensor error" on Canon printers

0 komentar

Error code 6A90 or "APP sensor error" occured during paper feeding or purging.

Solution 1:
check for foreign material or paper debris around the purge drive system unit;
- remove foreign material.
Solution 2:
check for foreign material or paper debris around the ASF unit;
- remove foreign material.Solution 3:
If other solution fail, replace one off the following part- Purge drive system unit
- Logic board. More information click here

Read More..

Copyright © 2010 Fix Your Printer By Self | Powered By Blogger